Chapter 2: Installation
98-141368-A 16
Mounting considerations for the terminal
Where to place the terminal
Temperature conditions
The terminal must be placed in a ventilated area with free space around all sides of the unit,
except the bottom side.
Ambient temperature range is –25 °C to +55 °C.
If the terminal is installed in a location where the ambient temperature may exceed 45 °C, we
recommend placing the terminal where unintentional contact is avoided. If the maximum
ambient temperature does not exceed 45 °C, the terminal can be placed in a public area.
Grounding access
The terminal is designed with a case for bulkhead or desktop installation. The case is equipped
with mounting brackets, making it possible to secure the unit on a bulkhead.
Important
The terminal must be placed in an area where access to the hull or equivalent
grounding can be reached within 0.5 m.